technical specifications | how a heat pump works | calculate pump size  >>

 

A Hi Temp Titanium Swimming Pool Heat Pump uses electricity to operate. They are actually a form of solar heater, as the sun-warmed air contributes to the efficiency of these units. This heat is extracted from the air, upgraded with a compressor, and then transferred to the water.

For those who enjoy swimming regardless of the weather, a
Hi Temp Titanium Heat Pump is the best option available. It is also the preferred method for therapy or athletic trainers, and also when a home is not "solar feasible" (i.e. solar will not fit on roof.) A Hi Temp Titanium heat Pump, when properly sized, can maintain any desired pool temperature between 28 and 35 degrees centigrade, regardless of outside weather conditions. A Hi Temp Titanium heat Pump will work when the outside air temperature is above 8 degrees centigrade.

Due to their high efficiency,
Hi Temp Titanium Heat Pumps have a low cost of operation. Typically, for every 20 cents of electric input, you receive R1.00 worth of heat. This is due to the coefficient of performance.

 

Why Heat My Pool?

You bought your pool for a number of reasons like family fun, exercise, entertaining and possibly even therapeutic reasons. However you've probably found that without heating your pool it's often too cold to enjoy. Heating your pool will allow you to enjoy it all season, perhaps all year round, thereby increasing the return on your sizable investment

 

Longevity and Maintenance

Hi Temp Titanium Heat pumps will typically last between 10 to 15 years or more. Because heat pumps are a mechanical device with many moving parts, they require periodic service by an A/C technician. 

 

Choosing the Right Type of Heating System

There are two basic types of pool heating systems: Solar, Electric Heat Pump. Deciding which system is best for you and your pool is determined by considering the factors below:

  • Water temperature desired

  • Swimming season desired

  • Geographic location / climate

  • Spending plans / project budget

  • The size/shape of the pool, plus shading/wind factors

  • Cost of operation

Hi Temp Titanium  Heat Pump Features

  • Heat water to your preferred temperature-set & go

  • Latest technology that is built to last

  • Easy to control LED display which can be installed on the unit or remote for easy access

  • 50mm standard coupling connections for easy installation

  • Silent and easy to operate

  • Very competitively priced – great value for money

All Hi TempTitanium heat pumps are quality tested at our factory prior to installation.

 

 

HI-TEMP HEAT PUMPS are manufactured to ISO 9001:2000 standards.

The CE mark of approval has been awarded.

 

Code

WBR-3.

8H-B

WBR-5.

3H-B

WBR-7.

8H-B

WBR-9.

5H-B

WBR-9.

5H-A

WBR-11.

3H-A

WBR-12.

5H-A

Rated heating capacity

W

3800

5300

7800

9500

9500

11300

12500

BTU

13000

18000

26500

32500

32500

38500

42500

Input power heating

W

791

1083

1625

1938

1980

2306

2550

Running current heating

A

3.6

5.0

7.5

8.8

8.8

10.6

11.7

EER

COP

4.9

4.9

4.8

4.9

4.8

4.9

4.9

Power supply

V/PH/HZ

220V/1PH/50HZ

Quantity of compressor

 

1

1

1

1

1

1

1

Compressor

 

Rotary

Quantity of fan

 

1

1

1

1

1

1

1

Input power of Fan

W

25

25

25

30

200

200

200

Fan rotate speed

RPM

890

950

950

950

830

830

850

Noise

dB(A)

52

55

55

58

60

60

60

Water connection

inch

1-1/2″

1-1/2″

1-1/2″

1-1/2″

1-1/2″

1-1/2″

1-1/2″

Water flow volume

m³/h

2-4

2-4

3-5

4-7

4-7

4-7

5-8

Water pressure drop

kpa

10

12

12

15

15

15

15

Refrigerant(R22)

kg

0.8

1.2

1.5

2.1

2.1

2.3

2.5

Dimension of outdoor

L

mm

795

950

950

1010

710

710

710

W

360

360

360

360

710

710

710

H

540

540

540

600

655

855

855

 Package size of outdoor

L

mm

890

1040

1040

1100

780

780

780

W

410

410

410

410

780

780

780

H

600

600

600

660

750

950

950

Weight

Net weight

kg

37

53

54

63

75

87

91

Gross weight

40

56

57

67

80

93

98

 

loading quantity

(1×40HQ)

 

 

 

 

 

 

 

 
Code

WBR-14.

0H-A

WBR-17.

0H-A

WBR-21.

0H-A

WBR-26.

0H-A

WBR-35.

0H-A

WBR-45.

0H-A

WBR-50.

0H-A

Rated heating capacity W

14000

17000

21000

26000

35000

45000

50000

BTU

48000

60000

73000

90000

120000

153000

170000

Input power heating

W

2980

3600

4550

5300 7900 9000 10300
Running current heating A

13.6

8.1

9.1

10.3

6.3×2

7.5×2

8.3×2

EER

COP

4.7

4.7

4.7

4.7

4.7

4.7

4.7

Power supply

V/PH/HZ

380V/3PH/50HZ

Quantity of compressor

 

1

1

1

1

2

2

2

Compressor Scroll

Quantity of fan

 

1

1

1

1

2

2

2

Input power of Fan

W

200

200

200

200

200×2

200×2

200×2

Fan rotate speed

RPM

850

830

830

830

830

830

830

Noise

dB(A)

60

60

60

60

61

61

61

Water connection

inch

1-1/2″

2″

2″

2″

3″

3″

3″

Water flow volume

m³/h

5-8

5-8

6-10

6-12

8-15

8-15

8-15

Water pressure drop

kpa

15

16

16

16

18

18

18

Refrigerant(R22)

kg

2.7

3.2

3.5

3.8

3.1×2

3.5×2

3.8×2

Dimension of outdoor

L mm

710

710

710

710

1500

1500 1500
W

710

710

710

710 845

845

845

H

855

955

955

955

1300

1300

1300
Package size of outdoor L mm

780

780

780

780

1650

1650

1650

W

780

780

780

780

980

980

980

H

950

1050

1050 1050

1450

1450

1450

Weight

Net weight

kg

105

108

111

112

240

250

260

Gross weight

113

120

123

125

270

280

290

 

loading quantity

(1×40HQ)              

Operation: when the average flow volume is 5-10cbm,and DB24Dgree,WB 19Dgree/water input 20degree

 

WBR-7.8H-B WBR-9.5H-B
WBR-3.8H-B

WBR-5.3H-B

WBR-11.3H-A

WBR-12.5H-A

WBR-14.0H-A

WBR-17.0H-A

WBR-21.0H-A

WBR-26.0H-A

WBR-35.0H-A

WBR-45.0H-A

WBR-50.0H-A

 

These units are essentially air conditioners that run in reverse.

 

Instead of removing the heat from inside a house and dumping it outside, heat is removed from the outside air and transferred to the swimming pool water via an exchange mechanism.

"Air Source" Heat Pumps utilize the sun's free heat by collecting and absorbing energy from the outside air. This energy is then compressed and transferred to the pool water.

 

Your existing pool pump circulates the water through the heater and warms the pool. The FAN circulates air through the outer EVAPORATOR AIR COIL that acts as a heat collector. The liquid refrigerant in the air coil absorbs the available heat in the ambient air transforming it into a gas. The refrigerant gas is then pumped into the COMPRESSOR. When this warmed gas is compressed, it intensifies or concentrates the heat like a magnifying glass in the sun. This intensely hot gas is then pumped into the HEAT EXCHANGER CONDENSER where the actual heat transfer takes place.

 

As the pool water passes through the heat exchanger, the hot gas gives up its heat to the cooler pool water. The refrigerant returns to a liquid state and is pumped through the EXPANSION VALVE then into the evaporator air coil to start the process all over again.

 

HI TEMP HEATPUMP SIZE CALCULATOR

1. Enter the pool length and depth or the pool area or the pool volume

  
    


2. Set Defaults

Initial Heating Time

MODEL NUMBER: 
 

Facebook Hi Temp Blog Twitter Flickr YouTube

© 2006 Home Technologies. All rights reserved. website designed by terri love designs